2013年12月10日星期二

Best exercises of EMC certification E20-361 exam and answers

Practice what you preach is the beginning of success. Since you have chosen to participate in the demanding IT certification exam. Then you have to pay your actions, and achieve excellent results. IT-Tests.com's EMC E20-361 exam training materials are the best training materials for this exam. With it you will have a key to success. IT-Tests.com's EMC E20-361 exam training materials are absolutely reliable materials. You should believe that you can pass the exam easily , too.

IT-Tests.com can provide professional and high quality products. It is the industry leader in providing IT certification information. To selecte IT-Tests.com is to choose success. IT-Tests.com's EMC E20-361 exam training materials is your magic weapon to success. With it, you will pass the exam and achieve excellent results, towards your ideal place.

If you use the IT-Tests.com EMC E20-361 study materials, you can reduce the time and economic costs of the exam. It can help you to pass the exam successfully. Before you decide to buy our EMC E20-361 exam materials, you can download our free test questions, including the PDF version and the software version. If you need software versions please do not hesitate to obtain a copy from our customer service staff.

Exam Code: E20-361
Exam Name: EMC (Network Attached Storage (NAS) Implementation Exam)
Free One year updates to match real exam scenarios, 100% pass and refund Warranty.
Total Q&A: 319 Questions and Answers
Last Update: 2013-12-10

IT-Tests.com have a strong It expert team to constantly provide you with an effective training resource. They continue to use their rich experience and knowledge to study the real exam questions of the past few years. Finally IT-Tests's targeted practice questions and answers have advent, which will give a great help to a lot of people participating in the IT certification exams. You can free download part of IT-Tests's simulation test questions and answers about EMC certification E20-361 exam as a try. Through the proof of many IT professionals who have use IT-Tests's products, IT-Tests.com is very reliable for you. Generally, if you use IT-Tests's targeted review questions, you can 100% pass EMC certification E20-361 exam. Please Add IT-Tests.com to your shopping cart now! Maybe the next successful people in the IT industry is you.

E20-361 (Network Attached Storage (NAS) Implementation Exam) Free Demo Download: http://www.it-tests.com/E20-361.html

NO.1 You are implementing a Celerra CIFS solution. When discussing the mapping method choices, the site
administrator asks you to explain the significance of the user mapping method for CIFS users.
How do you respond to the site administrator?
A.CIFS servers that join the Windows domain are assigned domain SIDs. The mapping method is used to
uniquely identify the CIFS servers in the Windows AD domain to UNIX NFS servicers in the NIS domain.
B.Celerra has a UxFS-based file system that requires UNIX style UIDs and GIDs for file and directory
permissions. Windows users and groups are identified with SIDs. The mapping method correlates UNIX
UIDs and GIDs to Windows SIDs for uniquely identifying users.
C.Celerra has a UxFS-based file system that stores UNIX style UIDs and GIDs and Windows SIDs for file
and directory permissions. The mapping method correlates the SIDs for local group permissions on the
CIFS server shares.
D.Stand-alone CIFS servers require a manual SID assignment when configured on a Celerra. When
users from the Windows domain access the Celerra the mapping method correlates the stand-alone CIFS
server SID with the Windows user SIDs.
Answer:B

EMC demo   E20-361   E20-361   E20-361 certification

NO.2 What is the default result of joining a CIFS server to a Windows Active Directory domain?
A.The CIFS server shares are dynamically updated in DNS.
B.The CIFS server interface is dynamically assigned from Active Directory.
C.The "EMC Celerra" container is created in Active Directory.
D.The CIFS server is added to the Active Directory Computers container.
Answer:C

EMC   E20-361 test   E20-361 answers real questions   E20-361 pdf

NO.3 File systems created for iSCSI LUNs should be large enough to accommodate which objects?
A.iSCSI LUNs and NFS
B.iSCSI LUNs and snaps
C.iSCSI LUNs and CIFS
D.iSCSI LUNs
Answer:B

EMC   E20-361   E20-361 demo

NO.4 Which component of SnapSure identifies changed data blocks in the production file system?
A.Bitmap
B.Blockmap
C.Superblock
D.Inode
Answer:A

EMC   E20-361   E20-361 questions

NO.5 The storage administrator would like to know if more AV servers are necessary for optimal
performance and protection.
Which tool can the system administrator use to analyze current utilization of the antivirus environment?
A.CAVA Calculator
B.NAS Support Matrix
C.CAVA Sizing Tool
D.Celerra Monitor
Answer:C

EMC exam   E20-361 exam   E20-361 certification   E20-361   E20-361

NO.6 ile systems created for iSCSI LUNs should be large enough to accommodate which objects?
A.iSCSI LUNs and NFS
B.iSCSI LUNs and snaps
C.iSCSI LUNs
D.iSCSI LUNs and CIFS
Answer:B

EMC   E20-361 test questions   E20-361   E20-361 original questions

NO.7 You have decided to use the Automatic SavVol Extension. For a Celerra of 200 GB a SavVol with 20
GB is created.
What is the size of the next Automatic SavVol Extension when HWM is reached?
A.20 GB
B.20 MB
C.64 MB
D.64 GB
Answer:A

EMC test answers   E20-361   E20-361 questions   E20-361

NO.8 Which Celerra Data Mover file controls both the services used for name resolution and the order in
which they are used?
A.nsswitch.conf
B.nslookup.conf
C.hosts.conf
D.resolv.conf
Answer:A

EMC   E20-361   E20-361   E20-361 answers real questions   E20-361 study guide

NO.9 Which describes how a Usermapper client resolves a Windows SID to UNIX UID/GID?
A.Uses the resolution order defined in the Data Mover nsswitch.conf file
B.Broadcasts over the internal Celerra network for secmap cache on server_2
C.Uses the ntxmap.conf file first, then the Data Mover secmap cache
D.Broadcasts over the internal Celerra network for a primary or secondary Usermapper service
Answer:D

EMC   E20-361 questions   E20-361   E20-361

NO.10 Which Celerra feature stores Windows SIDs correlated to UIDs and GIDs?
A.ntxmap
B.NASDB
C.secmap
D.SavVol
Answer:C

EMC braindump   E20-361   E20-361 exam dumps

NO.11 A Celerra file system has a SnapSure schedule enabled for daily checkpoints. By using the Microsoft
Shadow Copy Client, a user can see previous versions of a certain file up to a certain date in the past, but
nothing else after that.
What could be the cause of this issue?
A.Checkpoints are currently being used by an application.
B.All of the checkpoints have been refreshed.
C.There have been no changes to the file.
D.The SavVol has reached a full state.
Answer:D

EMC braindump   E20-361   E20-361

NO.12 You just created a new file system and exported it as an NFS export. You are informed that someone
deleted the .etc configuration directory.
What would be the best way to prevent this in the future?
A.Remove write permission on the .etc directory.
B.Export a subdirectory of the root file system.
C.Educate users about deleting system directories.
D.Set the hidden attribute on the root directory.
Answer:B

EMC   E20-361   E20-361   E20-361   E20-361

NO.13 What application provides integration between the Celerra and the iSCSI host for replicating an iSCSI
LUN?
A.Replication Manager
B.Unisphere Manager
C.Navisphere Manager
D.Celerra Manager
Answer:D

EMC test answers   E20-361   E20-361 test questions   E20-361 study guide   E20-361 answers real questions

NO.14 How is Kerberos used within the Active Directory?
A.For user authentication
B.Provides encryption of stored user passwords
C.For time synchronization
D.Provides Dynamic DNS updates
Answer:A

EMC   E20-361   E20-361   E20-361 demo

NO.15 You are implementing a CIFS solution and will possibly be using Virtual Data Movers. Which CIFS
dynamic configuration information is contained within the Virtual Data Mover?
A.Virus checker configuration
B.CIFS startup configuration
C.DFS root ID information
D.Share information
Answer:D

EMC exam simulations   E20-361 study guide   E20-361 certification training

NO.16 An administrator wants to present several CIFS shares to users through one file server. The shares are
stored on many physical machines. What can be used with the Celerra to achieve this goal?
A.Celerra global CIFS server
B.Default CIFS server
C.Distributed File System
D.Virtual Data Mover
Answer:C

EMC test   E20-361   E20-361 study guide   E20-361 answers real questions   E20-361 exam   E20-361

NO.17 You have moved a VDM from one Data Mover to another. Now the users cannot access the data. What
could cause this condition?
A.Interface names are different to the source VDM.
B.The IP address on the target Data Mover is set before the move.
C.Target Data Mover sees all file systems of the source VDM.
D.You keep the same IP addresses.
Answer:A

EMC braindump   E20-361 test answers   E20-361 exam simulations   E20-361

NO.18 How does the Control Station access disk partitions on the back-end storage?
A.FC
B.NBS
C.iFCP
D.iSCSI
Answer:B

EMC exam dumps   E20-361 exam prep   E20-361

NO.19 A user needs to test new software with existing data stored on a Celerra file system that has
checkpoints. The Celerra administrator is asked to mount a SnapSure checkpoint from the file system to a
different Data Mover.
Can the administrator fulfill this request? Why or why not?
A.Yes, but only if the checkpoint is mounted read-only
B.Yes, but the checkpoint cannot be restored to the PFS
C.No, because the checkpoint relies on the PFS
D.No, because a writeable snap is required for testing
Answer:C

EMC   E20-361 study guide   E20-361   E20-361 braindump   E20-361   E20-361

NO.20 Which statement describes Celerra gateway Fibre Channel connectivity between the blades and the
back-end storage?
A.CLARiiON back-end storage can only be connected to blades via direct connection.
B.Symmetrix back-end storage can only be connected to blades via direct
C.Symmetrix back-end storage can only be connected to blades via switched fabric.
D.CLARiiON back-end storage can only be connected to blades via switched fabric.
Answer:C

EMC   E20-361   E20-361 certification   E20-361 exam simulations

IT-Tests.com offer the latest 70-467 Questions & Answers and high-quality IIA-CGAP PDF Practice Test. Our 312-50v8 VCE testing engine and HP0-J60 study guide can help you pass the real exam. High-quality MB6-870 Real Exam Questions can 100% guarantee you pass the exam faster and easier. Pass the exam to obtain certification is so simple.

Article Link: http://www.it-tests.com/E20-361.html

没有评论:

发表评论